[HTML][HTML] Hemolytic anemia caused by aortic flap and inversion of felt strip after ascending aorta replacement
M Sakaguchi, T Takano - Journal of …, 2016 - cardiothoracicsurgery.biomedcentral …
… of the proximal inner felt strip was the cause of severe hemolysis, we describe … hemolytic
anemia at the site of aortic flap and inverted felt strip after replacement of the ascending aorta…
anemia at the site of aortic flap and inverted felt strip after replacement of the ascending aorta…
[PDF][PDF] A surgical case for hemolytic anemia after ascending and total arch replacement
Y Shingu, H Aoki, N Ebuoka, K Eya… - Annals of thoracic …, 2005 - researchgate.net
… replacement for DeBakey I type acute aortic dissection. The … of hemolytic anemia at the
site of inverted felt strip after total … A thrill was felt at the ascending aorta. The proximal …
site of inverted felt strip after total … A thrill was felt at the ascending aorta. The proximal …
Postoperative early hemolytic anemia due to inverted teflon felt strip after emergency repair for type A dissection
M Hata, I Yoshitake, S Wakui… - The Thoracic and …, 2011 - thieme-connect.com
… case complicated by hemolytic anemia due to an inverted Teflon felt strip without any
extra vascular factors after emergency graft replacement for type A acute aortic dissection (AAD). …
extra vascular factors after emergency graft replacement for type A acute aortic dissection (AAD). …
[HTML][HTML] Hemolytic anemia case caused by an inverted inner felt after Bentall operation
H Kang, JW Choe, DY Cho, DS Sohn… - Journal of Korean …, 2013 - synapse.koreamed.org
… tions, hemolysis associated with an inverted felt strip inversion is a … emergency repair for
type A dissection. Thorac Cardiovasc … after replacement of the ascending aorta for acute aortic …
type A dissection. Thorac Cardiovasc … after replacement of the ascending aorta for acute aortic …
Haemolytic anaemia resulting from the surgical repair of acute type A aortic dissection
Y Sekine, S Yamamoto, T Fujikawa… - … and thoracic surgery, 2014 - academic.oup.com
… months later, we performed descending thoracic aortic replacement. We … We removed the
felt strip and performed proximal … In conclusion, haemolytic anaemia caused by an inverted …
felt strip and performed proximal … In conclusion, haemolytic anaemia caused by an inverted …
… of three-dimensional transesophageal echocardiography for diagnosis of hemolytic anemia due to inverted internal felt strip after surgery for aortic dissection
T Oda, H Yasunaga, Y Zaima, A Arimura, S Imai… - Journal of Medical …, 2017 - Springer
… aortic stump fixation for AD is extremely rare. A 70-year-old woman underwent ascending
aorta replacement … , and the inverted internal felt strip was replaced with a bovine pericardial …
aorta replacement … , and the inverted internal felt strip was replaced with a bovine pericardial …
Hemolytic Anemia soon after Replacement of Ascending Aorta for acute Aortic Dissection
I Shibasaki, H Fukuda, Y Yamada, T Kuwata, H Ogawa… - 2015 - dmu.repo.nii.ac.jp
… )or jet of blood striking an inner felt strip4~7). We report a case of hemolytic anemia caused
by the inverted felt strip at the site after surgical treatment for aortic dissection using felt strips. …
by the inverted felt strip at the site after surgical treatment for aortic dissection using felt strips. …
… of Point-of-Care Transesophageal Echocardiography in the Intensive Care Unit for Detecting the Cause of Hemolytic Anemia After Ascending Aorta Replacement
Y Oshima, Y Seino, S Takagi, M Yamamoto… - … of Cardiothoracic and …, 2021 - Elsevier
… Most commonly, hemolysis after type A aortic dissection repair occurs in a delayed fashion,
… , hemolysis after ascending aortic replacement can occur due to inversion of Teflon felt strips …
… , hemolysis after ascending aortic replacement can occur due to inversion of Teflon felt strips …
Hemolytic anemia caused by kinking of Dacron grafts implanted in repair of after aortic dissection
F Sabzi, F Ghasemi, A Asadmobini - Ethiopian Journal of Health Sciences, 2016 - ajol.info
… for ascending aorta dissection treated by surgery and replaced … of the dissection flap in the
native aorta or an inverted strip was … Aortic stenosis caused by the felt strip used in repair for …
native aorta or an inverted strip was … Aortic stenosis caused by the felt strip used in repair for …
Aortic stenosis caused by the felt strip used in repair for acute aortic dissection
K Matsuura, H Ogino, K Minatoya… - … and Thoracic Surgery, 2004 - academic.oup.com
… ascending aorta to total arch replacement … hemolytic anemia due to stenosis of the proximal
anastomosis originating from a stiffened inner felt strip after repair for acute aortic dissection…
anastomosis originating from a stiffened inner felt strip after repair for acute aortic dissection…